<LOGO>
FM Transmitter Measurement Report
Created: 2024-02-01 00-19-07
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
87.90 MHz 5/5, 43 dBuV R-VYSOC
Pilot RDS Phase Difference
0.0 kHz 3.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
4 kHz 5 kHz 18873 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-3,8 dBr -1,89 dBr -0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-VYSOC " 2D09 9 (Varied) 1 0 1 1 0:18, 1.02.2024
RT
"Zpravy z regionu - rozhovory - dobre rady - souteze "
AF EON
87.9, 90.1, 96.5 MHz -
FM Scope Max at: 5 kHz MIN: 4 kHz % above 77 kHz: 0,0000 Acquired: 2024/02/01 0:19:04 Total samples: 18873 Equivalent time: 0:15:43 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000